Centauri Energy Server
Products
CENTAURI ENERGY SERVER
Key Attributes
Handles torque loads allowing start-up of motors, compressors, and all forms of inductive loads with surge currents, without oversizing the system.
Accepts 5x - 6x renewable input without oversizing the system.
Plug-and-Play connectivity to storage (does not require additional battery inverter for Sirius Energy Storage, Lead Acid or Li Ion).
Handles renewable intermittency by switching seamlessly between renewable generation and storage.
Directly supplies the load from renewable generation during generation hours (does not route through the battery).
Charges storage during generation hours (concurrently as it supplies the load).
Seamless switching between multiple input sources without destabilizing the load.
Energy blending capability for multiple input sources.
Actively corrects power factor losses to 1 on the circuit caused by inductive and capacitive loads.
Filters harmonics caused by the load.
Includes built-in safeties, data logging, monitoring, and control features.
Includes flexible protocols to communicate with and respond to signals from the grid.
It configurable to work in islanded or non-islanded modes. In non-islanded mode, is bi-directional.
Auto genset start / stop / control when genset is connected.
Modular and scalable.

Centauri Energy Server Products
Centauri Energy Server can be deployed in any location, to service any location, to service and kind of load profile (from kW to MW), with or without grid access or generator availability. The Centauri Energy Server is a fully integrated power electronics and software platform that requires no additional hardware or software to function. While the Centauri Energy Server can operate as a stand-alone device, it can communicate with external hardware and software if needed.
The Centauri Energy Server replaces inegrated systems comprised of multiple components (PV inverter + charge controller + battery inverter + communication software and hardware + safety devices etc.) in all use-cases. The Centauri Energy Server can be deployed, with energy storage, in:
- Oil and Gas Infrastructure
- Island States
- Prefabricated Houseing
- Displaced Persons’ Camps
- Disaster Relief
- Private Virtual Networks
- Data Centres
- Residential
- Commercial and Industrial
- University Campuses
- Mission Critical Facilities
- Military Bases
- Mines
- Agricultural Farms


Overload Handling Capacity

Centauri Advantage Over Legacy Systems
FEATURE | SIRIUS | LEGACY SYSTEM |
Torque Load Handling (Handles Surge Currents Enabling it to Independently Run all Types of Loads, Inductive, Resistive and Capacitive) | 1,000% for 2 sec | Not Available |
System Efficiency (Generation to Output) | 96,7% - 99,1% | 60% to 80% |
PV Connection | 6x Rated Capacity | 1,5x Rated Capacity |
Battery Inverter, Flexibility in Type of Battery Connectivity | Built-in (Supercapacitor Based / Lead Acid / Li Ion) | No-external |
Power Factor Correction of Load and Harmonics Filtering | Yes | No |
Multiple Source Input (AC or DC) | Yes-plug-and-play | No |
Blended Energy Output from Multiple Input Sources (AC and / or DC) | Yes | No |
Seamless Switching Between Sources | Yes | No |
Auto Genset Start / Stop / Control | Yes | No |
Islanding / Anti-islanding | Yes | No |
Bi-directional Option Available | Yes | No |
Built-in Safeties | Yes | No |
Modular | Yes | No |
Plug-and-play (No External Hardware or Software Required) | Yes | No |